Purpose: Aided speech-in-noise testing is commonly used by audiologists to assess functional listening abilities; however, no single speech-in-noise measure is universally adopted for cochlear implant candidacy evaluation (CICE) referrals. This study establishes CICE referral guidelines based on commonly used QuickSIN testing.
Method: Adults underwent bilateral QuickSIN and AzBio sentence testing with hearing aids verified to prescriptive targets during a CICE or routine hearing aid visit. Within-subject correlations between aided QuickSIN signal-to-noise ratio (SNR) losses and AzBio sentence scores at +5 dB SNR were calculated. Receiver operating characteristic (ROC) analysis was performed to identify the QuickSIN SNR loss that optimized sensitivity and specificity.
Results: Forty-nine adults with a median age of 74 (IQR 68-80) were included for analysis. The median QuickSIN SNR loss was 7.75 (IQR 3-14.75), while median AzBio sentence score with +5 dB SNR was 69% (IQR 31-85%). Aided QuickSIN SNR loss demonstrated a strong negative correlation with AzBio scores (Spearman’s rho = −0.941, p = 0.001). ROC analysis identified an aided QuickSIN SNR loss of ≥9 dB as the optimal referral threshold (AUC = 0.998) for CICE referral. Aided QuickSIN demonstrated improved sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for estimating audiologic CI candidacy when compared to the 60/60 guideline applied to the poorer hearing ear.
Conclusions: CICE referral decisions are often based on unaided pure-tone average and speech recognition in quiet, although insurance approval is frequently dependent upon speech-in-noise testing. Aided QuickSIN, a ubiquitous and easily administered test, may serve as a practical screening tool, and a bilaterally aided QuickSIN SNR loss of ≥9 dB can serve as a useful CICE referral tool in patients with bilateral hearing loss.